Leveraging adaptive comfort - the three-zone strategy

Using the three-zone approach to arrange a building's form and layout, so it can still operate when the electricity supply is interrupted.

Next, designers should use the ‘**three zone’** approach, to help arrange the building’s form, functions and detailed layout. This helps decide on the best responses to its urban / rural context, wind directions (for cross ventilation cooling and heat shedding), and the sun’s daily path – (anticipating the intensity of solar radiation falling on different parts of the building during the days, months and year). Because we are aiming for both Step 1 & 2 buildings to be able to operate during periods of disruption, including to the electricity supply, the 3 zone approach should be used to create buildings that can operate in naturally ventilated, passive mode whenever possible or necessary – no ARC-compliant buildings should be completely reliant for the thermal safety of its occupants on electricity-dependant mechanical systems alone, including systems using solar and battery backup.

All zones should be secure, insect-protected, well-shaded, and able to be effectively naturally ventilate. The building should also offer its occupants a survivable refuge from extreme heat events.


Source: ARC Technical Criteria - 129